Euphonix SH612 Switch User Manual


 
Euphonix SH612 Studio Hub User Guide Menu Reference and Technical Specifications
36
Time Code Free Wheel Duration
When the incoming time code signal is interrupted, the SH612 continues to generate
time code while it checks for the resumption of incoming time code within the period
specified in the Time Code Freewheel Duration setting. If the time code source re-
sumes before the Time Code Freewheel Duration, the SH612 checks to see if the dif-
ference between the current time code source frame value and the time code output
frame value is within 1% deviation.
If the difference is less than or equal to 1%, the SH612 resynchronizes to the
new time code source without interrupting time code or sample rate lock.
If the difference exceeds 1%, the SH612 drops time code and sample rate lock
and locks to the new time code position.
Drift Warning Threshold
Specifies the amount of drift that triggers the drift warning (1–100 frames).
LTC Output Gain
Specifies the output level of LTC in the range -2 to +10 dBv.