Euphonix SH612 Studio Hub User Guide Menu Reference and Technical Specifications
33
5.1.2 Sample Rate Setup Menu
Figure 5-3 Sample Rate Setup Menu
Custom Sample Rate
This parameter allows a user-specified sample rate in the range 31–100 kHz (default
value is 49000.0 Hz). To program a Custom sample rate:
1. Use the arrow keys to move the cursor under the sample rate digits.
Each digit is a separate field.
2. Use the SpinKnob to set the sample rate.
3. Press Select when the desired sample rate has been set.
This parameter can also be set in the Quick Setup menu.
Word Clock In Oversample
This feature allows a higher resolution Word Clock input to the SH612. The Word
Clock In Oversample value should match the incoming signal. The default is 1 which
does not alter the incoming signal and assumes a normal Word Clock sample rate. The
other options are 128 and 256 times the incoming rate.
Word Clock Out Oversample
Same options as Word Clock In Oversample.
Sample Rate Setup
Menu
Sample Rate
Source
Sample Rate
Word Clock In
Oversample Rate
Word Clock Out
Oversample Rate
Select Esc
AES
Select
Esc
Word Clock Internal Video Sync Video
TC Source
96000 Hz
Select
Esc
48000 Hz 44100 Hz
49000 Hz
Custom
Pull Up/
Pull Down Menu
Select
Esc
100000 Hz
PAL
96096 Hz
NTSC
95904 Hz
NTSC
92160 Hz
PAL
50000 Hz
PAL
48048 Hz
NTSC
47952 Hz
NTSC
46080 Hz
PAL
45937.5 Hz
PAL
44144 Hz
NTSC
44056 Hz
NTSC
42336 Hz
PAL
1
Select
Esc
128 256
1
Select
Esc
128 256