Extreme Networks 12804 Switch User Manual


 
Power Supplies for the BlackDiamond 12800 Series Switches
BlackDiamond 12800 Series Switches Hardware Installation Guide
151
Power Supplies for the BlackDiamond 12800 Series
Switches
This section lists specifications for the power supplies that are installed in the following BlackDiamond
switches:
BlackDiamond 12804 switch
BlackDiamond 12802 switch
Operating conditions Operating temperature range 0° C to 40° C (32° F to 104° F)
Operating humidity:10% to 93% relative humidity, non-condensing
Operating altitude 0 to 3000 meters (0 to 9,850 ft)
Operational shock: 30 m/s
2
(3 g), 11 ms, 60 shocks
Operational random vibration: 5 to 500 Hz @ 1.5g rms
Storage & transportation
conditions (packaged)
Transportation temperature: –40° C to 70° C (–40° F to 158° F)
Storage and transportation humidity: 10% to 93% relative humidity,
non-condensing
Packaged shock (half sine):
<50 kg 180 m/s
2
(10 g), 6 ms, 600 shocks, modules
>50 kg 100 m/s
2
(6 g), 11 ms, 600 shocks, chassis
Packaged random vibration: 5 to 20 Hz @ 1.0 ASD w/–3dB/oct. from 20 to
200 Hz
Packaged sinusoidal vibration: 5 to 62 Hz, 5 mm/s velocity, 62 to 200 Hz,
0.2 G
Tilt: 22.5 degrees and return to position
14 drops minimum on sides & corners
@ 39.4" <20 lb (9 kg) modules
@ 19.7" <80 lb (36 kg) chassis
Table 26: AC SSI PS Model #60020/PS2336 (700/1200 W AC PSU)
For the BlackDiamond 12804 switch
Typical configuration 3 power supplies
Full configuration 6 power supplies
Input Nominal input: 100 to 240 V , 60/50 Hz, 10 A max
AC voltage input range: 90 to 264 V
Maximum input amperages:
7 A @ 200 V (high-line)
10 A @ 90 V (low-line)
AC line frequency: 47 to 63 Hz
PS input socket: IEC 320 C14
Minimum wire size: 16 AWG (1.31mm
2
) copper stranded
Output DC output: 48 V , 24 A/12 V , 4 A (high-line)
48 V , 13.5 A/12 V , 4 A (low-line)
DC output power (W): 700 to 1200 W
Power supply cord selection Refer to “Selecting Power Supply Cords” on page 136.
AC power supply input socket IEC 320 C14
Minimum wire size 16 AWG (1.0mm
2
) copper stranded
(pre-approved cord set for county of use)
Operating conditions Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2
(3 g)
Table 25: BlackDiamond 12802 Switch Technical Specifications (Continued)