Extreme Networks 12804 Switch User Manual


 
Technical Specifications
BlackDiamond 12800 Series Switches Hardware Installation Guide
152
Table 27: DC SSI PS Model #60021 (1200 W DC PSU)
For the BlackDiamond 12804 switch
Typical configuration 3 power supplies
Full configuration 6 power supplies
Input Nominal input voltage: –48 V
Voltage input range: –40.5 V to –72 V
Input currents:
–40 V @ 35 A
–48 V @ 30 A
–60 V @ 23 A
Maximum in-rush current: Not more than 80 A for 5 ms
Input circuit protection: 50 A
Wire harness provided by Extreme Networks with each power supply.
Extreme Part# 4340-00028
Wire type: 8 AWG (10 mm
2
) listed tray cable, copper-stranded rated @ 90 C
minimum
Connector: Molex connector PN 42816-0312
Connector pins: Molex connector pins PN 42815-0032
Output DC output: 48 V , 24 A / 12 V , 4 A
DC output power (W): 1200 W
Operating conditions Operating temperature: 0° C to 40° C (32° F to 104 °F)
Operating humidity: 10% to 90% relative humidity, non-condensing
Operating altitude: 0 m to 3,000 m (0 ft to 9,850 ft)
Operational shock*: 30 m/s
2
(3 g), 60 shocks
Operational office vibration*: 5 to 100-5 Hz @ 2/10 G, 0 to peak, 1 oct/min
Operational random vibration*: 3 to 500 Hz @ 1.5 G rms
* Worst case operational condition; not for continuous operation under this
condition
Table 28: AC PS Model #65021 (325 W AC Power Supply)
For the BlackDiamond 12802 switch
Minimum configuration 2 power supplies
Full configuration 4 power supplies
Input Nominal input ratings: 100 to 240 V , 60/50 Hz, 4 A max
Operational voltage range: 90 to 264 V
Maximum input amperages:
3.5 A @ 115 V (low-line)
1.75 A @ 230 V (high-line)
AC line frequency: 47 to 63 Hz
AC power supply input socket: IEC 320 C14
Minimum wire size: 18 AWG (0.82mm
2
) copper stranded
(pre-approved cord set for county of use)
Output DC Output:
48 V , 6 A/12 V
2.5 A/7 VSB 0.75 A
Output power (W): 325 W
Operating conditions Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2
(3 g)