Extron electronic MTP U R RSA SEQ Switch User Manual


 
MTP U R Series • Installation
Installation
Installation
C Installation and service must be performed by
authorized personnel only.
The 1U high, quarter rack width, MTP U R receiver can be
mounted on a rack shelf, to a rack without a shelf, under a desk
or tabletop, or on a projector bracket.
UL guidelines for rack mounted devices
The following Underwriters Laboratories (UL) guidelines
pertain to the safe installation of the MTP U R receiver in a rack.
1. Elevated operating ambient temperature — If installed in
a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than
room ambient temperature. Therefore, install the device
in an environment compatible with the maximum ambient
temperature (Tma = +122 °F, +50 °C) specified by Extron.
2. Reduced air flow — Install the equipment in a rack so that
the amount of air flow required for safe operation of the
equipment is not compromised.
3. Mechanical loading — Mount the equipment in the rack
so that a hazardous condition is not achieved due to
uneven mechanical loading.
4. Circuit overloading — Connect the equipment to
the supply circuit and consider the effect that circuit
overloading might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this
concern.
5. Reliable earthing (grounding) — Maintain reliable
grounding of rack-mounted equipment. Pay particular
attention to supply connections other than direct
connections to the branch circuit (e.g., use of power strips).
Rack mounting
For optional rack mounting, mount the MTP on any of the
following rack shelves:
RSF 123, VersaTools
®
19" 1U rack shelf kit
(part #60-190-20)
RSB 123, VersaTools 19" basic 1U rack shelf
(part #60-604-21)
RSU 126, 6" deep 1U rack shelf kit (part #60-190-10)
RSB 126, 6" deep basic 1U rack shelf (part #60-604-11)
8