MTP U R Series • Installation
Installation, cont’d
10
N
Fxtron recommends where more than one shelf is
required, rack mount shelves are installed at least 1U
apart, to allow for air flow and proper cooling between
the shelves.
3. Install false faceplate(s) or other unit(s) to the rack shelf.
4. Mount the shelf into the rack.
Back of the rack mounting
The MTP can be mounted to the rear of a rack using the Extron
MBB 100, VersaTools
®
back of the rack mounting kit
(part #70-367-01). The kit allows the product to be vertically
mounted to the front or rear rack supports and facing either
towards the front or the rear of the rack.
MT P S ERIES
Figure 10 — Attaching the back of the rack kit
1. Remove feet from the bottom of the MTP if they are
installed.
2. Remove two screws from one side of the unit. Retain the
screws for possible later reassembly without the bracket.
3. Attach one bracket to the side of the unit using the longer
screws included in the kit.
4. Repeat steps 2 and 3 on the other side of the unit.
5. Mount the unit to the rack using the two included rack
screws (figure 11). The MTP can be vertically mounted
facing in either direction.