Extron electronic MTP U R RSA SEQ Switch User Manual


 
MTP U R Series • Installation
22
Installation, cont’d
N
A 2-nanosecond (ns) adjustment is very fine. Up to
10 ns of delay may be necessary before a change in the
display is detectable. Maximum delay possible is 62
nanoseconds.
c. Use a Tweeker or other small screwdriver to press the
Select button one more time to save the most recent
adjustment or allow the 10-second timeout to elapse.
4. If the remaining color is left shifted, repeat step 3.
Non-SEQ receivers skew compensation
Try using the following methods to minimize or eliminate pair
skew:
Switch to Extron’s Enhanced Skew-Free A/V UTP cable.
Add a skew compensation cable equal to the length of
pair skew to the receiver’s output.
Install an SEQ 100 15HD Skew Equalizer on the receiver’s
video output and adjust the skew for the leading video
image.