Extron electronic PVS 405D Switch User Manual


 
SIS command definitions
X10) = Default name: combination of model name and last 3 hex pairs of MAC address
(for example PVS‑405D‑06‑DE‑2E).
X10$ = Hardware (MAC) address: (00‑05‑A6‑xx‑xx‑xx)
X11) = Verbose/Response mode, (default = 0 for telnet connections, 1 for RS‑232 and USB host
control).
0 = Clear/none;
1 = Verbose mode
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries.
NOTE: If tagged responses is enabled, all read commands will return the constant string +
the data, like setting the value does.
For example command: E CN } response: Ipn X10^]
X11@ = Baud rate:
0 = 9600 (Default)
1 = 19200
2 = 38400
3 = 115200
X11*
= Unit name is a text string up to 24 characters drawn from the alphabet (A‑Z), digits (0‑9),
minus sign/hyphen (‑). No blank or space characters are permitted as part of a name.
No distinction is made between upper and lower case. The first character must be an alpha
character. The last character must not be a minus sign/hyphen.
X12) = Firmware Query (‘Q’ commands)
*Q = Firmware and build number [<X.YY.ZZZZ> ]
0Q = Verbose version information [<2Q> ‑ <3Q> ‑ < 4Q>] sum of responses
from 2Q‑3Q‑4Q.
1Q = Firmware version [<currently running code (X.YY)>]
2Q = Final stage bootloader (Uboot) version [<X.YY>]
3Q = Factory base code version [<factory base code (X.YY)>*]
4Q = Updated firmware version [<updated code version (X.YY)>*]
PVS 405D • SIS Communication and Control 21