RS-232 Connector Wiring
Figure 33 shows the wiring for the PVS 405D and the MLC 104 IP Plus RS‑232
connectors .
MLC 104 IP Plus
right side panel
MLS and
Power
ports
PVS 405D
Remote RS-232
Port
RS-232 12V
MLS PWR
AB
Rx
Tx
GROUND
GROUND
+12V IN
G
Ground
+12 VDC input
Ground all devices.
External Power Supply
(12 VDC, 4 A)
NOTE:
If you use cable that has
a drain wire, tie the drain wire
to ground at both ends.
NOTE:
You must connect
a ground wire between
the MLC and PVS 405D.
REMOTE
RS-232
Tx Rx G
Ground (Gnd)
Transmit (Tx)
B
G
Receive (Rx)
A
Transmit (Tx)
Receive (Rx)
B
A
Figure 33. RS-232 Connector Wiring
From MLC 104 IP Plus
terminal
Wire color To PVS 405D terminal
A ‑ (Rx on the MLS port) White A ‑ (Tx on the RS‑232 port)
B ‑ (Tx on the MLS port) Violet B ‑ (Rx on the RS‑232 port)
MLS RS‑232 Ground Drain wire
G ‑ Ground
Power Ground Black To PVS 405D Power Supply
12 V In Red To PVS 405D Power Supply
ATTENTION: The length of the exposed (stripped) copper wires is important.
The ideal length is 3/16 inch (5 mm). Longer bare wires can short together.
Shorter wires are not as secure in the connectors and could be pulled out.
Wire Bared
3/16"
(5 mm)
Max.
7/8"
(22 mm)
Heat Shrink on
Outer Jacket to
Inner Conductor
Transition
Heat Shr
ink on
Drain
Wire
Figure 34. Connector Wire Preparation
NOTES:
The MLC 104 IP Plus is powered from the PVS 405D associated power supply.
Do not tin the power supply wires before installing them in the direct insertion
connector. Tinned wires are not as secure and could be pulled out.