Extron electronic PVS 405D Switch User Manual


 
Command ASCII (Telnet)
(host to switcher)
Response
(switcher to host)
Additional Description
Query updated
firmware
version
4Q
X12)]
Use this command to find out which
version of firmware has been uploaded
into the processor post‑factory.
Example:
4Q Ver04*1.00
In this example, firmware version is 1.00.
Information requests
Request switcher part
number
N
60-1235-01
]
Show switcher part number.
Verbose response
Pno60-1235-01]
Request AV input
number
I
Vid
X!•AudX!]
Show current active video and audio
inputs.
Request model name
1I PVS 405D
Show device name
Verbose response
Inf01*PVS 405D
]
Request model
description
2I PoleVault Digital
Switcher
Show device description
Verbose response
Inf02*PoleVault
Digital Switcher
]
Read hardware
address (MAC)
ECH} X10$] X10$ = hardware media access control
(MAC) address (xx-xx-xx-xx-xx-xx).
Verbose response
Iphxx-xx-xx-xx-xx-
xx
]
Set verbose mode
24
EX11)CV} VrbX11)]
Set verbose mode.
Read verbose mode
ECV} X11)]
Verbose response
Vrb
X11)]
Set unit name
EX11*CN} IpnX11*] Set the unit name. (X11* up to 24
alphanumeric characters). Special
characters (spaces or blanks) not allowed.
Set unit name to
factory default
ECN} IpnX10)]
Set the unit name back to default. Default
name X10) is a combination of model
name and last 3 hex pairs of MAC address
(for example PVS‑405D‑06‑DE‑2E).
View unit name
ECN} X11*] View the current unit name (X11*).
Reset (Zap) command
Reset all device settings
to factory
E ZXXX} Zpx] E ZXXX command resets all video and
audio settings
NOTE: X! = Video and audio input selection, 1‑5
X10) = Default name: combination of model name and last 3 hex pairs of MAC address (for example PVS‑405D‑06‑DE‑2E).
X10$ = Hardware (MAC) address: (00‑05‑A6‑xx‑xx‑xx)
X11) = Verbose/Response mode, (default = 0 for telnet connections, 1 for RS‑232 and USB host control). 0 = Clear/none,
1= Verbose mode, 2 = Tagged responses for queries, 3 = Verbose mode and tagged responses for queries.
X11* = Unit name is a text string up to 24 characters drawn from the alphabet (A‑Z), digits (0‑9), minus sign/hyphen (‑).
No blank or space characters are permitted as part of a name. No distinction is made between upper and lower case. The
first character must be an alpha character. The last character must not be a minus sign/hyphen.
X12) = Firmware Query (‘Q’ commands)
*Q = Firmware and build number [<X.YY.ZZZZ> ]
0Q = Verbose version information [<2Q> ‑ <3Q> ‑ < 4Q>] sum of responses from 2Q‑3Q‑4Q.
1Q = Firmware version [<currently running code (X.YY)>]
2Q = Final stage bootloader (Uboot) version [<X.YY>]
3Q = Factory base code version [<factory base code (X.YY)>*]
4Q = Updated firmware version [<updated code version (X.YY)>*]
PVS 405D • SIS Communication and Control 29