Getting started Turning the FortiGate unit power on and off
FortiGate-60 Installation Guide 01-28008-0018-20050128 15
Power requirements
• DC input voltage: 12 V
• DC input current: 3 A
Environmental specifications
• Operating temperature: 32 to 104°F (0 to 40°C)
• Storage temperature: -13 to 158°F (-25 to 70°C)
• Humidity: 5 to 95% non-condensing
Turning the FortiGate unit power on and off
To power on the FortiGate unit
1 Connect the AC adapter to the power connection at the back of the FortiGate-60 unit.
2 Connect the AC adapter to the power cable.
3 Connect the power cable to a power outlet.
The FortiGate-60 unit starts. The Power and Status LEDs are on.
To power off the FortiGate unit
Always shut down the FortiGate operating system properly before turning off the
power switch.
1 From the web-based manager, go to System > Maintenance > ShutDown, select
Shut Down and select Apply, or from the CLI, enter:
execute shutdown
2 Disconnect the power supply.
Table 1: FortiGate-60M LED indicators
LED State Description
Power Green The FortiGate unit is powered on.
Off The FortiGate unit is powered off.
Status Green The FortiGate unit is starting up.
Off The FortiGate unit is running normally.
Link
(Internal
DMZ
WAN1
WAN2)
Green The correct cable is in use and the connected
equipment has power.
Flashing Green Network activity at this interface.
Off No link established.
100
(Internal
DMZ
WAN1
WAN2)
Green The interface is connected at 100 Mbps.