Fortinet FortiGate-5000 Network Card User Manual


 
The FortiGate-5005-DIST security system FortiGate-5005-DIST interface names
FortiGate-5000 Series Introduction
01-30000-83466-20090108 71
FortiGate-5050 chassis
You can install one or two I/O boards in slot 1 and 2 of the FortiGate-5050 ATCA
chassis. You can also install up to three worker boards in slots 3 to 5 if two I/O
boards are being used, or four worker boards in slots 2 to 5 if one I/O board is
used. The FortiGate-5050 is a 5U chassis that contains two redundant DC power
connections that connect to -48 VDC Data Center DC power. The FortiGate-5050
chassis also includes a hot swappable cooling fan tray. For details about the
FortiGate-5050 chassis, see the FortiGate-5050 Chassis Guide.
Figure 33: FortiGate-5005-DIST components installed in a FortiGate-5050 chassis
FortiGate-5005-DIST interface names
The FortiGate-5005-DIST worker web-based manager and CLI use an internal
naming convention to name FortiGate-5005-DIST interfaces. The interface names
indicate the I/O board containing the interface and also include the I/O board front
panel interface name. The naming convention is:
port<I/O_board_number>_<I/O_board_interface_name>
where:
<I/O_board_number> is 1 for the interfaces of the primary I/O board installed in
chassis slot 1 and 2 for the interfaces of the secondary I/O board installed in
chassis slot 2. The interfaces for the secondary I/O board only appear in the
web-based manager and CLI when a secondary I/O board is installed.
<I/O_board_interface_name> is the name of the interface as shown on the
FortiController-5208 front panel.
Table 24 on page 72 shows the relationship between the names of the primary
and secondary board front panel interfaces and the interface names that appear
on the FortiGate-5005-DIST worker web-based manager and CLI.
1
2
2
3
4
5
SMC
1
SMC
POWER
5050SAP
SERIAL
1
SERIAL
2
ALARM
10/100
link/Act
ETH0
Service
RESET
STATUS
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
10/100
link/Act
ETH0
Service
RESET
STATUS
Hot Swap
link/Act
ETH0
ETH1
10/100
5000SM
PAYLOAD OPERATION
STATUS
IPM
X 1
X 2
1/2 3/4 D15/D16 C15/C16
1
2
3
4
5
6
7
8
9
10
11
12
D
13
14
15
16
D
1
2
3
4
5
6
7
8
9
10
11
12
C
13
14
15
16
C
10/100/1000 MBPS ETHERNET ACTIVITY
DATA CONTROL
1
2
3
4
MANAGEMENT
COM 1 COM 2
X 1 X 2
CONSOLE
ACT
ACT
LINK
LINK
FABRIC
BASE
USB USB
3 412 56
78
OOS ACC STATUS
IPM
CONSOLE
ACT
ACT
LINK
LINK
FABRIC
BASE
USB USB
3 412 56
78
OOS ACC STATUS
IPM
CONSOLE
ACT
ACT
LINK
LINK
FABRIC
BASE
USB USB
3 412 56
78
OOS ACC STATUS
IPM
CONSOLE
ACT
ACT
LINK
LINK
FABRI C
BASE
USB USB
3 412 56
78
OOS ACC STATUS
IPM