Fujitsu C141-E252-01EN Computer Drive User Manual


 
2.1 Hardware Specifications
2.1.3 Environmental specifications
Table 2.3 lists environmental and power requirements.
Table 2.3 Environmental/Power requirements (1/2)
Specification
Item
MBA3300RC MBA3174RC MBA3073RC
Operating 5 to 55 °C
Non-operating –40 to 70 °C
Transport –40 to 70 °C
DE surface temperature at
operating
5 to 60 °C
Temperature
(*1)
Gradient 20 °C/h or less
Operating 5 to 95 %RH
Non operating 5 to 95 %RH
Transport 5 to 95 %RH
Relative
humidity
Maximum wet bulb temperature 29 °C (no condensation)
Operating (*3) 0.6 mm (5 to 20Hz) / 9.8 m/s
2
(1G) (20 to 300 Hz) or less
Non-operating (*4) 3.1 mm (5 to 20Hz) / 49 m/s
2
(5G) (20 to 300Hz) or less
Vibration
(*2)
Transport (packaged) 3.1 mm (5 to 20Hz) / 49 m/s
2
(5G) (20 to 300Hz) or less
Operating 637.4 m/s
2
(65G) (2ms)
Non-operating 2451.7 m/s
2
(250G) (2ms)
Shock (*2)
Transport (packaged) 2451.7 m/s
2
(250G) (2ms)
Operating –305 to +3,048 m (–1,000 to +10,000 feet)
Altitude
Non-operating –305 to +12,192m (–1,000 to +40,000 feet)
Regulation ±5%
Ready (average) 0.88A 0.60A 0.45A
Spin up
2.5A (peak)
3.5A (less than 100µs)
Peak operating
current
Maximum (peak)
DC (*6)
2.8A 2.5A 2.3A
+12V DC
Peak operating
current
DC (reference) (*6)
1.15A 0.9A 0.75A
Regulation
±5%
Ready (average)
0.5A
Peak operating
current
Maximum (peak)
DC (*6)
1.5A
Power
requirement
(*5)
+5V DC
Peak operating
current
DC (reference) (*6)
0.79A
C141-E252 23