Fujitsu C141-E252-01EN Computer Drive User Manual


 
Installation Requirements
46 C141-E252
(5) Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the HDD. At designing the system cabinet, consider following points.
Make a suitable air flow so that the DE surface temperature never exceed 60°C.
Cool the PCBA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring the surface temperature of specific ICs and the DE. These measurement results
must satisfy the temperature condition listed in Table 4.1.
Keep the DE surface temperature at 50°C or below to meet the condition for assuring an MTBF
of 1,400,000 hours. An air flow of 0.5 m/s or more is required at ambient temperature 30°C.
Table 4.1 Surface temperature check point and maximum temperature
No. Measurement point Maximum temperature
1 DE Surface 60°C
2 Read channel LSI 82°C
3 VCM/SPM Driver 100°C
4 HDC 97°C
5 MPU 94°C
Figure 4.5 Surface temperature measurement points