21
Appendix C Replacing Parts
■ Part No. and Replacement Cycle
for Consumable Parts
The usage count of consumable parts can be checked in
the "Usage Status" screen on the [Device Status] tab.
When parts need to be replaced soon, the "Status" infor-
mation field becomes orange. When parts need to be
replaced immediately, the "Status" information field
becomes red.
The following table specifies the replacement part num-
bers and the standard replacement cycles.
To obtain these parts, contact your FUJITSU dealer or
an authorized FUJITSU scanner service provider.
These replacement cycles are rough guidelines when
using 64 g/m
2
(17 lb) A4/Letter woodfree or wood con-
taining paper. They may vary according to the type of
documents scanned, scanner usage, and cleaning fre-
quency.
The following diagram shows the locations of the con-
sumable parts in the scanner. For more details, refer to
the "Operator's Guide".
■ Pad Assembly (PAD ASSY)
■ Pick Roller
The glass scanner windows
inside the ADF can become hot
when the scanner is used.
Before cleaning inside the
scanner or replacing any parts,
turn off the power, unplug the AC
adapter from the outlet, and wait
for at least 15 minutes.
Part Name Replacement Cycle
Pad assembly
(Pad ASSY)
(PA03289-0111)
After every 50,000 sheets
scanned or once a year
Pick roller
(PA03289-0001)
After every 100,000 sheets
scanned or once a year
ATTENTION
Use only the PFU LIMITED parts
specified. Do not use consumable
parts made by other manufacturers.
Pick roller
Pick roller's shaft
fi-6010N Network Scanner Getting Started
22
■ Part No. and Replacement Cycle
for Carrier Sheet
One "Carrier Sheet" is provided with the scanner. If the
"Carrier Sheet" provided with the scanner can no longer
be used for scanning due to damage or wear-and-tear,
you can purchase a new Carrier Sheet separately.
The following table specifies the replacement number
and the standard replacement cycle for carrier sheets.
Contact your FUJITSU scanner dealer or an authorized
FUJITSU scanner service provider to obtain these prod-
ucts.
This replacement cycle is a rough guideline. This may
vary according to the type of documents scanned, scan-
ner usage, and cleaning frequency. If parts become
noticeably dirty, replace them accordingly.
The following diagram shows the Carrier Sheet.
For more details, refer to the "Operator's Guide".
■ Carrier Sheet
Part Name
No. of
items
Replacement Cycle
Carrier Sheet
(PA03360-0013)
5 After used for 500
scans
ATTENTION
Use only the PFU LIMITED parts
specified. Do not use parts made by
other manufacturers.