Fujitsu MPG3XXXAH-E Computer Drive User Manual


 
C141-E116-01EN 5 - 67
READ DMA WRITE LONG SECURITY DISABLE PASSWORD
READ LONG WRITE MULTIPLE SECURITY FREEZE LOCK
READ MULTIPLE WRITE SECTORS SECURITY SET PASSWORD
READ SECTORS WRITE VERIFY FORMAT TRACK
READ VERIFY SET MAX ADDRESS FLASH CACHE
WRITE DMA
At command issuance (I-O registers setting contents)
1F7
H
(CM) 11110101
1F6
H
(DH)
×××
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
xx
xx
At command completion (I-O registers contents to be read)
1F7
H
(ST) Status information
1F6
H
(DH)
×××
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
xx
Error information
(34) SECURITY SET PASSWORD (F1h)
This command enables a user password or master password to be set.
The host transfers the 512-byte data shown in Table 5.15 to the device. The device determines the
operation of the lock function according to the specifications of the Identifier bit and Security level
bit in the transferred data. (Table 5.16)
Issuing this command in LOCKED MODE or FROZEN MODE returns the Aborted Command
error.