Fujitsu MPG3XXXAH-E Computer Drive User Manual


 
C141-E116-01EN4 - 20
d) During phase switching, the spindle motor starts rotating in low speed, and generates a counter
electromotive force. The SVC detects this counter electromotive force and reports to the MPU
using a PHASE signal for speed detection.
e) The MPU is waiting for a PHASE signal. When no phase signal is sent for a specific period,
the MPU resets the SVC and starts from the beginning. When a PHASE signal is sent, the
SVC enters the acceleration mode.
(2) Acceleration mode
In this mode, the MPU stops to send the phase switching signal to the SVC. The SVC starts a
phase switching by itself based on the counter electromotive force. Then, rotation of the spindle
motor accelerates. The MPU calculates a rotational speed of the spindle motor based on the
PHASE signal from the SVC, and accelerates till the rotational speed reaches 7,200 rpm. When
the rotational speed reaches 7,200 rpm, the SVC enters the stable rotation mode.
(3) Stable rotation mode
The MPU calculates a time for one revolution of the spindle motor based on the PHASE signal
from the SVC. The MPU takes a difference between the current time and a time for one revolution
at 7,200 rpm that the MPU already recognized. Then, the MPU keeps the rotational speed to 7,200
rpm by charging or discharging the charge pump for the different time. For example, when the
actual rotational speed is 7,400 rpm, the time for one revolution is 8.108 ms. And, the time for one
revolution at 7,200 rpm is 8.333 ms. Therefore, the MPU discharges the charge pump for 0.225
ms × k (k: constant value). This makes the flowed current into the motor lower and the rotational
speed down. When the actual rotational speed is later than 7,200 rpm, the MPU charges the pump
the other way. This control (charging/discharging) is performed every 1/4 revolution.