Fujitsu PRN608-S Printer User Manual


 
PRN608-S
28-03-2003 Page 2-11 of 53
i. 0 (Default)
ii. 1
iii. 2
iv. 3
v. 4
vi. 5
vii. 6
viii. 7
ix. 8
x. 9
r. Burn strobe light
i. -1
ii. -2
iii. -3
iv. -4
v. -5
vi. -6
vii. -7
viii. -8
ix. -9
Settings will be effective upon turn off and on.
* FTP628MCL00x/30x must be set as 384 dots.
* FTP6x8MCL05x/1xx and FTP6x8MCL35x is auto detected.
2.6 Serial Input/Output
If BUSY control is selected:
When 236 bytes of data have been stored in the input buffer, the
SBUSY signal becomes high to request that the computer temporarily
stop sending data. When the amount of data stored in the input buffer
becomes 235 bytes or less, the SBUSY signal changes to low to
request that the host device continue data transfer. Up to 16 bytes of
input data are guaranteed after the SBUSY signal has become high.
When an error occurs, the SBUSY signal becomes high. Data input is
prohibited until the error is cancelled.
If Xon/Xoff control is selected:
When 188 bytes of data has been stored in the input buffer, Xoff (13
16
)
is output through the TxD terminal to request that the host device
temporarily stops sending data. When the amount of data stored in the
input buffer becomes 124 bytes or less, Xon (11
16
) is output to request
that the computer continues data transfer. Up to 64 bytes of the input
data are guaranteed after
Xoff has been output. When an error occurs, the Xoff signal is output to
prohibit the data input.