Fujitsu PRN608-S Printer User Manual


 
PRN608-S
28-03-2003 Page 3-26 of 53
[Description] When the printer controller receives this byte the digital
value of the head temperature will be transmitted. This
command can be treated even if buffer is full
3.8.25 Sub command set
[Name] Sub command set
[Format] ASCII ESC n
Hex 1B n
Decimal 27 n
[Range] n: [-128;127]
[Description] The n is the commands in the sub-set.
3.8.26 Upgrade command
[Name] Upgrade command
[Format] ASCII ESC Z
Hex 1B 5A
Decimal 27 90
[Description] Only used by the I/F-COM A/S upgrade programs.
3.8.27 Set auxiliary output
[Name] Set auxiliary output
[Format] ASCII ESC p n
Hex 1B 70 n
Decimal 27 112 n
[Description] When this command is received then
the auxiliary output can be set.
If n = 0, then the output will be set to off
If n > 1 and < 254 then the output will
be turned on in n/4.096msec, and then
turned off again.
If n = 255, then the output will be turned
on.
3.8.28 Automatic sending status
[Name] Automatic sending status
[Format] ASCII ESC a
Hex 1B 61
Decimal 27 97
[Description] When this command is sent once, then the
board will transmit the status every time that
it change state.