PRN608-S
28-03-2003 Page 3-23 of 53
barcode 39, and the ‘*’ can only be used as start and
end character.
If the barcode length exceeds the paper size the last
barcode character will not be written as barcode. In that
case the barcode cannot be read because the last
character will not be ‘*’
3.8.11 Feed Forward
[Name] Feed Forward
[Format] ASCII FF
Hex 0C
Decimal 12
[Description] When this command is received the printer will print
whatever data it has in the buffer and feed forward
50mm
3.8.12 Reverse off
[Name] Reverse off
[Format] ASCII SO
Hex 0E
Decimal 14
[Description] This command will switch off reverse printing
3.8.13 Reverse on
[Name] Reverse on
[Format] ASCII SI
Hex 0F
Decimal 15
[Description] This command will switch on reverse printing
3.8.14 Underline off
[Name] Underline off
[Format] ASCII DLE
Hex 10
Decimal 16
[Description] This command will switch off underline printing
3.8.15 Underline on
[Name] Underline on
[Format] ASCII DC1