132 Operating Manual RX600 S6
Appendix: server specification
Dimensions (Base unit specific)
Environmental
Rack mounting kit Rack mounting kit as option
Rack (W x D x H) 482.6 mm (Bezel) / 444.8 mm (Body) x 765.0 mm x
176.0 mm
Mounting Depth Rack 728 mm
Height Unit Rack 4 U
19" rackmount Yes
Mounting cable depth
rack
100 mm (1000 mm rack recommended)
Noise emission Measured according to ISO 7779 and declared
according to ISO9296
Sound pressure
(LpAm)
< 50 dB(A) (standby)
< 50 dB(A) (operation)
Sound power (LWAd;
1B = 10dB)
< 6.5 B (standby)
< 6.6 B (operation)
Noise notes /
description
at ambient temperature < 23°C
Operating ambient
temperature
10 - 35°C
Operating relative
humidity
10 - 85 % (non condensing)
Exhaust air volume Ambient temp. m
3
/h m
3
/min
<25°C 49 0.82
30°C 87 1.45
35°C 126 2.1