Fujitsu RX600 S6 Server User Manual


 
RX600 S6 Operating Manual 89
CSS components
Ê Slide the new power supply unit into the empty slot until it clicks into place.
I Make sure that the new power supply unit engages correctly in the
mounting location and is locked in position. This is the only way to
prevent the power supply unit from sliding out of its mountings and
being damaged during transportation.
Ê Thread the cable through the cable clamp (see figure 6 on page 54).
Ê Pull the cable clamp tight to secure the power cord.
Ê Connect the newly installed power supply unit to the mains.
If everything is functioning correctly, the green LEDs 1 and 3 (see "Indicators
on the hot-plug power supply units" on page 67) at the rear of the power
supply unit will now light up.
8.1.1.2 Adding a hot-plug power supply unit
Figure 15: Removing a PSU dummy module
Ê Remove the PSU dummy module as follows:
1. Press the two metal clips together (see arrows (1) in figure above).
2. Pull the PSU dummy module out of its slot (see arrow (2) in figure above).
Ê Slide the new power supply unit into the empty slot until it clicks into place.
I Make sure that the new power supply unit engages correctly in the
mounting location and is locked in position.This is the only way to prevent
the power supply unit from sliding out of its mountings and being
damaged during transportation.
//
0