Fujitsu RX600 S6 Server User Manual


 
RX600 S6 Operating Manual 61
Starting up and operation
5.1.1.3 Indicators on the accessible drives/components
Optical drive activity indicator
Lights up green when the storage medium is being accessed.
ServerView Local Service Display
You can use the slot mechanism to pull out the ServerView Local Service
Display from the server housing and read the information. Press the front of the
module to release the lock.
You can also pivot the ServerView Local Service Display down by an angle of
120° from its normal position. This makes reading easier when the server is
located very high in the rack.
Further information on using the ServerView Local Service Display is provided
in the "Customer Self Service (CSS)" manual.
Global Error indicator (orange)
Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
Flashes orange if an error was detected that requires service
intervention.
Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), on the ServerView Local Service Display, in the
ServerView Operations Manager or via the iRMC S2's Web
interface.
!