RX600 S6 Operating Manual 133
Appendix: server specification
Electrical values
Power supply
configuration
Up to 4 hot-plug power supplies
Base unit equipped with 2 power supplies;
redundancy as option
Max. output of single
power supply
850 W
Hot-plug power supply
redundancy
Yes
Rated voltage range 100 - 127 V / 200 - 240 V
Rated frequency range 50 - 60 Hz
Active power min.
(typical config)
750 W
Active power max.
(typical config)
1800 W
Rated active power max. 2640 W (11 A x 240 V)
Apparent power max.
(per system unit)
1830 VA
Heat emmission 6480.0kJ/h = 6141.6 BTU/h