Fujitsu RX600 S6 Server User Manual


 
50 Operating Manual RX600 S6
Hardware installation
Installation requirements for AC non redundant configurations
For systems not requiring AC redundancy, the power supply subsystem can be
installed with up to 4 PSUs. The PSUs can be connected to a single or multiple
AC sources.
Three power supply modules are capable of handling the maximum power
requirements for a fully configured PRIMERGY RX600 S6 server system, which
include the following:
Four processors
1024 GB of memory
Eleven PCIe add-in cards (including the SAS/SATA RAID controller card)
Eight hard disk drives and/or solid state disks
One optical drive
One tape drive
The hot swap feature allows the user to replace a failed power supply module
without affecting the system functionality.
PSU Configuration Max. DC Loading DC Redundancy
1+1 (2 PSUs) 830W Yes
2+1 (3 PSUs) 1580W Yes
3+1 (4 PSUs) 2320W Yes
Table 3: Maximum DC Loading Requirements