Furuno RD-30 Computer Monitor User Manual


 
1. OPERATION
1-10
5. Use the cursor pad to select “A” and then press the [ENT] key. The data
available for display is shown.
NONE
TEMP
DEPTH
SOG
STW
HDG
COG
XTE
WIND
ODO
TRIP
POSN
TD
TIME
WPT
ROT
TIMER
POWER
CUR
PRE
A-TEMP
HUM
NONE
ETA
Digital display options
6. Select data desired and then press the [ENT] key. (All data require
appropriate sensors.)
NONE: No display
TEMP: Water temperature
DEPTH: Depth
SOG: Speed over ground
STW: Speed through water
HDG: Heading
COG: Course over ground
XTE: Cross-track error
WIND: Wind speed and direction
ODO: Odometer
TRIP: Trip distance
CUR: Current (tide)
POSN: Position in latitude and longitude
TD: Position in Loran C or Decca TDs
TIME: Date and time
WPT: Waypoint (selected at navigator)
ROT: Rate of turn
TIMER: Remaining time for time alarm
POWER: Power source voltage
CUR: Current (tide) speed and direction
PRE: Atmospheric pressure
A-TEMP: Atmosphere temperature
HUM: Humidity (relative or absolute)
ETA: Estimated Time of Arrival (at destination waypoint)
7. For 2-, 3- and 4-indication displays repeat step 5-6 to select data as
appropriate.
Note 1: A digital display shows bars (-) where corresponding data is not
available or input is lost.
Note 2: ETA display requires the sentences ZDA and ZTG or ZTG and RMC.
8. Press the [MENU] key twice to close the menu.
1.5.3 Setting up graph displays
1. Select GRAPH referring to paragraph 1.5.1.
2. Press the [ENT] key to show the graph display options window.