Furuno RD-30 Computer Monitor User Manual


 
1. OPERATION
1-18
1.7.5 Arrival alarm, anchor watch alarm
The arrival alarm informs you that your boat is approaching a destination
waypoint. The area that defines an arrival zone is that of a circle which you
approach from the outside of the circle. The alarm will be released if your boat
enters the circle.
The anchor watch alarm informs you that your boat is moving when it should be
at rest.
The arrival alarm and anchor watch alarm cannot be activated together. RMB,
BWR or BWC data sentence required for these alarms.
Your ship's position
where you start the
anchor watch alarm.
Alarm
setting
: Alarm
area
: Alarm area
Own ship
Alarm
range
Destination
waypoint
Anchor watch alarm
Arrival alarm
How the arrival alarm works
1. Press the [MENU] key once or twice to show the main menu.
2. Select ALARM2 and then press the [ENT] key.
ALARM2
ARV/ANC: OFF 0.50NM
XTE : OFF 0.25NM
TRIP : OFF 0NM
ODOMETER: OFF 0NM
TIME : OFF 00:00
COUNTDOWN: OFF 5MIN
ALARM2 menu
3. Select ARV/ANC and then press the [ENT] key to show the arrival
alarm/anchor watch alarm options window.
OFF
ARV
ANC
Arrival/anchor watch alarm options window