Furuno RD-30 Computer Monitor User Manual


 
1. OPERATION
1-31
CALIBRATION ?
ARE YOU SURE ?
YES NO
Calibration prompt
6. Choose YES and then press the [ENT] key. The display shows
“CALIBRATION??” during calibration. (To cancel calibration, press the
[MENU] key. You cannot cancel calibration except when SAMPLING is
showing “??”.)
7. Continue turning the boat in a circle until calibration results, NG (No Good) or
OK, appear on the display. This takes about 3-5 circles with the PG-1000 or
2-3 circles with the C-2000. If the calibration was successful, OK appears as
the results.
CALIBRATION
SAMPLING : OK
CALIBRATION : OK
RESULT : OK
Calibration results
8. The display then shows “PUSH ENT KEY.” Push the [ENT] key to return to
the HDG SETUP menu.
Note: If the results were unsuccessful, NG appears as the results. In this
case, press the [MENU] key or the [ENT] key to return to the HDG
SETUP menu. Redo the calibration referring to the installation manual
for the heading sensor.
9. If you do not need to align heading or enter a damping factor (C-2000), press
the [MENU] key twice to close the menu. To align heading, go to step 10. To
enter damping factor, go to step 18.