Furuno RD-30 Computer Monitor User Manual


 
1. OPERATION
1-12
4. Use the cursor pad to select an item and then press the [ENT] key. The
far-left digit is selected by the cursor in the case where you enter data, or a
pop window appears with options. Enter and select data referring to the table
below.
To enter numeric data: Use or to select location and or to enter
value and change from plus to minus and vice versa.
For pop-up window: Use the cursor pad to select desired option.
Graph setup menus
Menu
Item Description Setting Range Default Setting
Temp Graph
Setup
Base Point:
Set reference temperature.
Range:
Set the range for the graph.
Period:
Set the interval at which to
update graph data.
Base Point:
-99˚F - +999˚F
Range:
1˚F -900˚F
Period:
5, 30 min; 1, 3, 6, 12,
24, 48, 72, real*
Base Point:
+50˚F
Range:
10˚F
Period:
5 min
Depth Graph
Setup
Start From:
Set starting depth.
Max Range:
Set the range for the graph.
Period:
Set the interval at which to
update graph data.
Start From:
0-9998 ft
Max Range:
1-9999 ft
Period:
5, 30 min; 1, 3, 6, 12,
24, 48, 72, real*
Start From:
+ 0 ft
Max Range:
300 ft
Period:
5 min
SOG Graph
Setup
Start From:
Set starting speed.
Max Range:
Set the range for the graph.
Period:
Set the interval at which to
update graph data.
Start From:
0-998 kt
Max Range:
1-999 kt
Period:
5, 30 min; 1, 3, 6, 12,
24, 48, 72, real*
Start From:
+ 0 kt
Max Range:
30 kt
Period:
5 min
STW Graph
Setup
Start From:
Set starting speed.
Max Range:
Set the range for the graph.
Period:
Set the interval at which to
update graph data.
Start From:
0-998 kt
Max Range:
1-999 kt
Period:
5, 30 min; 1, 3, 6, 12,
24, 48, 72, real*
Start From:
+ 0 kt
Max Range:
30 kt
Period:
5 min
Wind Graph
Setup
Start From:
Set starting wind speed.
Max Range:
Set the range for the graph.
Period:
Set the interval at which to
update graph data.
Start From:
0-998 kt
Max Range:
1-999 kt
Period:
5, 30 min; 1, 3, 6, 12,
24, 48, 72, real*
Start From:
+ 0 kt
Max Range:
20 kt
Period:
5 min
Current
Graph Setup
Start From:
Set starting current speed.
Max Range:
Set the range for the graph.
Period:
Set the interval at which to
update graph data.
Start From:
0-998 kt
Max Range:
1-999 kt
Period:
5, 30 min; 1, 3, 6, 12,
24, 48, 72, real*
Start From:
+0 kt
Max Range:
20 kt
Period:
5 min
Pressure
Graph Setup
Start From: Set starting pressure.
Max. Range: Set the range for the graph.
Period: Set the interval at which to update
graph data.
Start From:
0800-1199 hPa
Max Range:
0801-1200 hPa
Period:
5, 30 min; 1, 3, 6, 12,
24, 48, 72, real*
Start From:
+ 0800
hPa
Max Range:
1200 hPa
Period:
5 min
* = Every second
5. Press the [ENT] key to register setting.
6. Press the [MENU] key twice to close the menu.
Base point (+50 F)
Range (-5 F)
period (5 min.)
55
45
(5 MIN)
50
TEMP (- -. - - F)