Galil DMC-1400 Tablet Accessory User Manual


 
HX
FUNCTION: Halt Execution
DESCRIPTION:
The HX command halts the execution of any of the two programs that may be running
independently in multitasking. The parameter n specifies either program to be halted.
ARGUMENTS: HX n where
n is either 0 or 1 to indicate the task number
USAGE:
While Moving Yes Default Value n = 0
In a Program Yes Default Format ---
Command Line Yes
Can be Interrogated No
Used as an Operand Yes
Controller Usage
ALL
OPERAND USAGE:
When used as an operand, _HX n contains the running status of thread n with:
0 Thread not running
1 Thread is running
2 Thread has paused at trippoint
RELATED COMMANDS:
XQ Execute program
EXAMPLES:
XQ #A Execute program #A, thread zero
XQ #B,1 Execute program #B, thread one
HX0 Halt thread zero
HX1 Halt thread one
100 HX DMC-1400 Series Command Reference