72 EA DMC-1400 Series Command Reference
EA
FUNCTION: Choose ECAM master
DESCRIPTION:
The EA command selects the master axis for the electronic cam mode. Any axis may be
chosen. Note: This command is only used with the DMC-1425. All other Econo series
controllers use the auxiliary encoder as the master automatically.
ARGUMENTS: EA x where
x is one of the axis specified as X or Y.
USAGE:
While Moving Yes Default Value
In a Program Yes Default Format
Command Line Yes
Controller Usage
DMC-1425
RELATED COMMANDS:
EB Enable ECAM
EC Set ECAM table index
EG Engage ECAM
EM Specify ECAM cycle
EP Specify ECAM table intervals & staring point
EQ Disengage ECAM
ET ECAM table
EXAMPLES:
EAY Select Y as a master for ECAM