Galil DMC-1400 Tablet Accessory User Manual


 
46 BV DMC-1400 Series Command Reference
BV
FUNCTION: Burn Variables and Array
DESCRIPTION:
The BV command saves the defined variables and arrays in non-volatile EEPROM memory.
This command typically takes up to 2 seconds to execute and must not be interrupted.
The controller returns a : when the Burn variables is complete. Operand returns size of
installed EEPROM.
ARGUMENTS: None
USAGE:
While Moving No Default Value ---
In a Program No
Command Line Yes
Can be Interrogated No
Used as an Operand Yes
Controller Usage
DMC-1412/1414/1415/1416/1425
Note1: This command will store the ECAM table values in non-volatile EEPROM memory.
Note2: This command may cause the Galil software to issue the following warning "A time-out
occurred while waiting for a response from the controller". This warning is normal and is designed to
warn the user when the controller does not respond to a command within the timeout period. This
occurs because this command takes more time than the default timeout of 5 sec. The timeout can be
changed in the Galil software but this warning does not affect the operation of the controller or
software.