GBC 930-032 Laminator User Manual


 
Operations Manual: Installation
Voyager 3
Voyager 3
2004 General Binding Corporation
Page 4-2
CA
UTION:
Do not locate the laminator where
air can blow directly on the machine. The air
flow can cool the rollers unevenly and result
in poor quality output.
Have you contacted a certified electrician to
install a receptacle for the laminator ensuring
that adequate power and correct circuit
breaker is being supplied?
The laminator and heater requires 380 Volt
AC, 50/ 60 Hz, 50 amps, Delta three phase
(four wire) power. For US, a transformer is
required to step up power from 230 Volt
3 Phase to 380 Volt 3 Phase AC. Refer to
Figure 4.1.2 connections.
For heater requirements, consult the heater
manual for your unit.
INFORMA
TION: The vacuum/ pump, feeder
and heater units will draw its electrical power
from the laminator.
Is tap and drain water available?
Water supply should be hard plumbed with a
3/4 in. (1.9 cm) NPT supply and drain. Refer
to Figure 4.1.2 connections.
Is proper air pressure available?
Air pressure required is 80-90 psi min.
(0.56-0.63 Mpa) with an air flow of 10-13 cfm
(280-360 liters/ min.). Refer to Figure 4.1.2
connections.
CA
UTION: Tripping Hazard. If connections
are not dropped from the ceiling, all lines and
hoses must be covered to prevent trip hazard.