GBC 930-032 Laminator User Manual


 
Operations Manual: Installation
Voyager 3
Voyager 3
2004 General Binding Corporation
Page 4-3
Figure 4.1.1 Suggested Floor Layout
MANUFACTURE OR FOR ANY OTHER PURPOSE WITHOUT WRITTEN
COPIED OR DISCLOSED IN WHOLE OR IN PART, OR USED FOR
FOR ENGINEERING INFORMATION ONLY AND SHALL NOT BE
REPRODUCED,
GBC PRO-TECH CLAIMS PROPRIETARY RIGHTS TO THE
MATERIAL DISCLOSED ON THIS DRAWING. IT IS ISSUED IN CONFIDENCE
PERMISSION FROM GBC PRO-TECH
PROPRIETARY
C
GBC Films Group
4151 Anderson Road, DeForest, WI 53532
This print is the property of GBC Films Group. The information thereon is remitted in confidence.
UNLESS OTHERWISE SPECIFIED
TOLERANCE
DIM. AS
SHOWN
TOL.
+
1/64
+
.050
+
.020
+
.010
+ .005
X/X
X
XX
XXX
XXXX
ANGLES
+ 1D
FINISH
TO BE
125
TITLE :
DATE : DRAWN BY :
DWG SCALE : DWG :
REVISION
CHECKED BY : GBC FILMS GROUP
Suggested Floor Layout
GBC Voyager 3
Figure 4.1.1N/ASNF
10/31/02
> 2 ft.
(61 cm)
> 5 ft.
(152 cm)
> 2 ft.
(61 cm)
> 5 ft.
(152 cm)
16 ft.
(488 cm)
Detail A-A
Align heater with
edge of feeder motor
Air supply drop
Electrical drop
(Laminator)
Water supply drop
4 ft.
(122 cm)
3.5 ft.
(107 cm)
6 ft.
(183 cm)
Electrical (Europe):
- 400 Vac
- 50 hz
- 75 amps
- 3 phase (four wire)
Air:
- 8 Bar Max
(112 psi / 800 MPa)
- 10-12 CFM
(280-360 liters/ min.)
Water:
(Recommended)
- Tap water
- Drain return
Laminator Requirements
Electrical (US):
- 230 to 400 Vac
- 60 hz
- 100 amps
- 3 phase (four wire)
Transformer Required
- 230 to 400 Vac
- 3 phase (four wire)
Heater Requirements
See Heater Manual For
Details.
Electrical drop
(Heater)