Operations
Section 5.1 Controls
The operator control panel for the Falcon 160
Laminator is located on the front of the machine, to the
right of the front operating position.
For an illustration of the complete front control
panel, please refer to Figure 5.1.1. The names and
functions of these controls are as follows:
INFORMATION
When any command is pressed on the
control panel, a "beep" will sound. If the
command is held down, the panel will
"beep" only once.
( 1 ) SLEEP : If flashing, the machine is in sleep mode.
This will occur after 3 hours of no activity. To wake the
laminator from sleep mode, press any command.
TOP TEMP.
BOT. TEMP
SLEEP
32
32
1
( 2 ) TOP TEMP DISPLAY : The display will show
the set point temperature of the top main roller as the
default display. When the top roller temperature has
reached in the +/- 10
o
F range of the set point, the
display will be solid. When outside of this range, the
display will flash.
TOP TEMP.
BOT. TEMP
SLEEP
32
32
2
( 3 ) TOP TEMP s : When pressed, will increase the
set point value of the top main roller in increments of 2
degrees. If held down, it will only increase to the
maximum temperature setting of 290
o
F ( 143
o
C ).
TOP TEMP.
BOT. TEMP
SLEEP
32
32
3
( 4 ) TOP TEMP t : When pressed, will decrease the
set point value of the top main roller in increments of 2
degrees. If held down, it will only decrease to the
minimum temperature setting of 68
o
F ( 20
o
C ).
TOP TEMP.
BOT. TEMP
SLEEP
32
32
4
( 5 ) BOT. TEMP. DISPLAY : The display will show
the set point temperature of the bottom main roller as
the default display. When the bottom roller temperature
has reached in the +/- 10
o
F range of the set point, the
display will be solid. When outside of this range, the
display will flash.
TOP TEMP.
BOT. TEMP
SLEEP
32
32
5