GBC F - 160 Laminator User Manual


 
F - 160 Operation and Maintenance Manual
© GBC Pro - Tech August 1999Page 5 - 2
Operations
( 6 ) BOT. TEMP. s : When pressed, will increase
the set point value of the bottom main roller in
increments of 2 degrees. If this key is held down, it will
only increase to the maximum temperature setting of
290
o
F ( 143
o
C ).
TOP TEMP.
BOT. TEMP
SLEEP
68
68
6
( 7 ) BOT. TEMP. t : When pressed, will decrease
the set point value of the bottom main roller in
increments of 2 degrees. If held down, it will decrease
to the minimum temperature setting of 68
o
F ( 20
o
C ).
TOP TEMP.
BOT. TEMP
SLEEP
68
68
7
( 8 ) GAP DISPLAY : Displays the current main roller
nip opening. The nip has a range of 0 to 1” gap.
GAP
PRESSURE
1/4
8
( 9 ) GAP s : When pressed, will increase the gap by
1/16 in. increments. If held down, it will automatically
increase the gap by 1/16 in. increments until it has
reached a maximum opening of 1 in. on the GAP
DISPLAY.
GAP
PRESSURE
1/4
9
( 10 ) GAP t : When pressed, will decrease the gap
by 1/16 in. increments. If held down, it will
automatically decrease the gap by 1/16 in. increments
until it has reached a minimum opening of 0 in. on the
GAP DISPLAY.
GAP
PRESSURE
1/4
10
( 11 ) PRESSURE DISPLAY : Displays the amount
of pressure being used. Each bar represents 10% of the
maximum allowable pressure. All ten bars illuminated
equals 100% of the maximum allowable pressure.
GAP PRESSURE
1/4
11
INFORMATION
When adjusting the pressure, the gap
will be affected as well.
( 12 ) PRESSURE s : When pressed once, will
decrease the pressure by 5%. If held down, it will
decrease from 100% of the maximum allowed pressure
to 0% at which point no bars will be illuminated.
GAP
PRESSURE
1/4
12