GE GFK-2489 Network Router User Manual


 
GFK-2489 Chapter 4 Remote Radio Management
4-5
4
Detailed Command Descriptions
ALARM Displays the current alarm conditions by severity level. For each level, the
specific events that caused an alarm are listed, along with a brief description of
each alarm. Alarm levels are:
ALL—All alarm classes
INFORM—Non-persistent information
MINOR—Minor alarm
MAJOR—Major alarm
CRITICAL—Critical alarm
Optional argument:
HEX= —Displays the hex bit codes for the current alarm condition by class. For
each specific event that causes an alarm, the corresponding bit is set. Event
numbers are matched to the appropriate hex code by a relationship of 2
n
.
APLIST Configures a list of approved APs.
Optional arguments:
APx=<integer> Configures a list of approved APs. X is a number from 1–50,
and integer is the serial number of an approved AP (1–99999999). To delete
an entry, enter a serial number of 0; this indicates that the slot is not filled.
AP1=<integer>Serial Number of approved AP
AP2=<integer>Serial Number of approved AP .
-to-
AP50=<integer>Serial Number of approved AP
CLEAR—Clears all entries in the AP list. Be sure to set RESTRICT to OFF
before using this command to avoid restricting Remotes to associating with an
empty list.
CMD—Displays all settable optional arguments and their current values. You
can copy this list to a text file as a record of your configuration.
RESTRICT=<ON|OFF>—Turns on or off restricting registration to APs in the
list.
ON—The Remote can only associate with an AP on the list.
OFF—The Remote can associate with any AP.