Graco 24B591 Network Card User Manual


 
Setup
28 313855H
Low Level Filtering Screen Setup
The Low Level Filtering screen setup is used to filter out
spurious signals from rotating paddle type low level sen-
sors.
NOTE: When using the GLC4400 with the G3 Automatic
Lubrication Pump, it is recommended that the low level
filtering be set to G3 defaults.
The NUMBER field determines how many signal activa-
tions are required to set a fault.
The TIME field determines the amount of RUN time
required without an activation to reset the activation
count to 0 (zero).
1. Use the Arrow keys to move the cursor over the
NUMBER field.
2. Press ENTER.
3. Use the UP/DOWN arrows to move up and down
through the numbers 0-9 until the first number you
want in the NUMBER field is displayed.
4. Use the RIGHT arrow to move the cursor to the next
field. Repeat step 3.
NOTE: The maximum number of Counts you can setup
in this field is 99.
5. Use the Arrow keys to move the cursor over the
TIME field.
6. Press ENTER.
NOTE: Time is displayed in HH:MM:SS.
7. Use the UP/DOWN arrows to move up and down
through the numbers 0-9 until the first number in the
TIME field is displayed.
8. Use the RIGHT arrow to move the cursor to the next
field. Repeat step 7.
9. Repeat steps 7 and 8 until the desired time is dis-
played.
10. Press ENTER.
11. If the default values for the G3 Automatic Lubrica-
tion Pump are intended to be used, use the
UP/DOWN arrows to move to the G3 DEFAULT
field.
12. Press ENTER. The NUMBER and TIME values will
be updated to the G3 default value.
13. Press RESET. The Main Screen, shown on page
18, displays.
F