Graco 24B591 Network Card User Manual


 
Technical Data
34 313855H
Technical Data
Input Contact
Power Source DC - model 24B591 9 - 30 VDC
Power Source AC - model 24B596 100 VAC to 240 VAC - 50/60 Hz
Power consumption 24 Watts
Cycle Pressure Control Input (optional) Normally open pressure or cycle switch
Machine Count Control Input (optional) Machine count control switch
Lubrication level (optional) Normally open level switch, closes upon low level
Remote Manual Run Input Normally open remote manual run switch
Outputs
Pump control Pump Control Voltage = Power Source
Voltage Power Source
Max Switching Voltage 250 VAC, 100 VDC
Max Switching Current 10 A (AC), 5A (DC)
Minimum Switching Capacity 100 mA @ 5 VDC
Low Level Alarm, normally open (optional)
Voltage Power Source
Max Switching Voltage 250 VAC, 30 VDC
Max Switching Current 5A (AC), 5A (DC)
Minimum Switching Capacity 100 mA @ 5 VDC
Auxiliary Alarm, normally open (optional)
Voltage Power Source
Max Switching Voltage 250 VAC, 30 VDC
Max Switching Current 5A (AC), 5A (DC)
Minimum Switching Capacity 100 mA @5 VDC
Status OK, normally open (optional) Voltage-free Contact
Voltage Power Source
Max Switching Voltage 250 VAC, 100 VDC
Max Switching Current 10 A (AC), 5A (DC)
Minimum Switching Capacity 100 mA @ 5 VDC
Protection grade
IP69K
Enclosure Material Fiberglass reinforced polyester
Membrane Material Polyester
Bushing Ethylene Propylene Diene Monemer Rubber (EDPM)
Operating temperature range - 40°F to 145°F (- 40°C to 63°C)
Storage Temperature - 13°F to 145°F (- 25°C to 63°C)