H
TTP Up
g
rade
Server
The URL for the web server used for firmware upgrade and configuration via HTTP. For
example, http://provisioning.mycompany.com:6688/Grandstream/1.0.6.0
Here “:6688” is the specific TCP port that the HTTP server is listening to, it can be omitted if
using default port 80.
Note: Auto Upgrade has to be set to Yes to enable HTTP upgrade. TFTP and HTTP options
are mutual exclusive.
Automatic HTTP
Upgrade
Choose Yes to enable HTTP upgrade and provisioning.
In “Check for new firmware every” field, enter the number of days to check the HTTP server
for firmware upgrade or configuration.
Subscribe for MWI:
Default is NO. When set to Yes a SUBSCRIBE for Message Waiting Indication will be sent
periodically.
Offhook
Auto-Dial
This parameter allows a user to configure a User ID or extension number to be automatically
dialed upon offhook. Please note that only the user part of a SIP address needs to be entered
here. The HandyTone ATA will automatically append the “@” and the host portion of the
corresponding SIP address.
Note: Please write down the IP address of the ATA if you use this feature as it will disable the
IVR and the only way to access it is via web configuration page.
Enable Call Features
Default is Yes. Call Forwarding & Do-Not-Disturb are supported locally
Disable Call Waiting
Default is No. User can use * code to use this feature per call basis.
Send DTMF
This parameter controls the way DTMF events are transmitted. There are 3 ways: in audio
which means DTMF is combined in audio signal (not very reliable with low-bit-rate codec), via
RTP (RFC2833), or via SIP INFO.
DTMF Payload Type
This parameter sets the payload type for DTMF using RFC2833
Send Flash Event
This parameter allows a user to control whether to send an SIP NOTIFY message indicating the
Flash event, or just to switch to the voice channel when the user presses the Flash key. Default
is NO.
FXS Impedance
Selects the impedance of the analog telephone connected to the Phone port.
Caller ID Scheme
Select the Caller ID Scheme to suit the standard of different area.
On-hook Voltage
Select the on-hook voltage to suit different area or PBX.
Polarity Reversal
Select Polarity Reversal to adapt some call charge/billing system. Default is NO.
NTP server
This parameter defines the URI or IP address of the NTP (Network Time Protocol) server
which the HandyTone ATA will use to display the current date/time.
Send Anonymous
If this parameter is set to “Yes”, the “From” header in outgoing INVITE message will be set to
anonymous, essentially block the Caller ID from displaying.
Lock keypad update
If this parameter is set to “Yes”, the configuration update via keypad is disabled.
Special Features
Default is Standard. Choose the selection to meet some special requirements from Soft Switch
vendors like Nortel, Broadsoft, etc.
WAN side http access
Default is “No”. The access to configuration page via WAN port is disabled. Need to change to
“Yes” if user wants WAN side HTTP access to the ATA.