HP (Hewlett-Packard) 200 All in One Printer User Manual


 
SHIFT
Accuracy
Calib. Print
7Ć7 CalibrationsC3187Ć90000
   
Enter service mode D page 7Ć2.
Plot a service configuration plot D page 8Ć23.
Measure the distance between the centers of the X" marks on the configuration plot.
An accuracy calibration is needed if this distance is not
500 mm (20 in) 1 mm (0.04 in) under normal environmental conditions.
If the measured accuracy, media thickness, or environmental conditions vary greatly from
the factory standards, recalibrate the plotter by continuing with the following steps.
Place a sheet of media (preferably inkjet polyester film) over the top of the plotter for 10
minutes to let the sheet stabilize to the environmental conditions.
Use a sheet approximately 61 x 91 cm 24 x 36 in.
Select the appropriate
Media Type on the front panel.
Load the media in portrait orientation into the plotter.
If using inkjet polyester film, load the film with the matte dull side down.
When the
Ready LED lights up, hold down the
SHIFT key and press Accuracy Calib. Print.
The Busy LED lights up and the plotter plots a
calibration plot. The plotter ejects the sheet,
and the
Load Media
LED lights up.
Unload the sheet.
Reload the sheet  into the plotter, in the direction indicated by the arrows on
the calibration plot.
If the plotter is D/A1 size, the sheet does not fit in the entry slot in the orientation
indicated by the arrows. In this case, cut the blank end off the media so that it fits.
Cut along the long line on the plot; the cut must be very straight so that the sheet can
be loaded.
For D/A1-size plotters,
cut along this line