Table 3-4 Configuration Options
Config Name Description Default
RECOVERY
ON/OFF
If the configuration is set to ON, the library attempts to recover
from errors. If the configuration is set to OFF, the library
immediately stops moving if an error occurs. The default
configuration is RECOVERY ON and should remain ON under
normal conditions.
ON
RESTORE
DEFAULTS
Sets all library configurations back to their default settings. —
CLEAR
ODOMETERS
Used by service personnel only. Sets all library odometers back to
zero.
—
STARWARS
ON/OFF
Used by service personnel only and should be set to ON during
normal operation. If the configuration is set to ON, the library
runs with the vertical sensors enables. If the configuration is set to
OFF, the library runs with vertical sensors disabled.
ON
NEW PASSWORD Allows you to change the numerical password required to access
the options under the ADMIN * menu on the library control panel.
These options include configurations, tests, and information logs.
To change the password, see “Setting a New Administration Menu
Password” on page 3-10.
—
SCSI LOG
ON/OFF
Used by service personnel only, and should be set to OFF
during normal operation. Tracks internal SCSI states and saves
the information to a log.
OFF
SECURE ON/OFF When set to ON, tape magazines cannot be loaded or removed. If
the configuration is set to OFF, the library operates in its default
state, which allows cartridges to be loaded and removed.
OFF
POWER SECURE
ON/OFF
When set to ON, the SECURE ON/OFF configuration setting is
retained in the event of a power outage. If this configuration is set
to OFF, the library returns to its default setting of POWER SECURE
OFF when power is returned after being shut off.