HP (Hewlett-Packard) 545740-002 Server User Manual


 
NotesRequired Cabinet (Rack)
Location
Height (U)Enclosure or Component
Required when you have
less than four cabinets
bayed together. Cabinet
stabilizer is not required
when cabinet is bolted to its
adjacent cabinet.
Bottom front exterior of
cabinet
N/ACabinet stabilizer
There is a limit of one
installed c7000 enclosure
per cabinet.
Must be installed at U9
when there is no UPS
Must be installed at U11
when there is a UPS and
ERM
10Uc7000 enclosure
IP CLIMs should be
adjacent to one another in a
group of four, so the CLIMs
can share one quad optic
port on the c7000 ServerNet
switch.
Any available 2U space.
Upper U locations are
recommended.
2UIP CLIM
Storage CLIMs and disk
enclosures should be
adjacent to one another.
Storage CLIMs should be
adjacent to one another
in a group of two, so the
CLIMs can share one
quad optic port on the
c7000 ServerNet switch.
Any available 2U space.
Upper U locations are
recommended.
2UStorage CLIM
disk enclosures and Storage
CLIMs should be adjacent
to one another.
Any available 2U space.
Middle or upper U locations
are recommended.
2USAS disk enclosure
IOAMs and FCDMs should
be adjacent to one another.
Any available 11U space.
Middle or upper U locations
are recommended.
11UIOAM enclosure
IOAMs and FCDMs should
be adjacent to one another.
Restricted service clearances
might exist with a Fibre
Channel disk module
installed adjacent to the
maintenance switch.
Any available 3U space.
Middle or upper U locations
are recommended.
3UFibre Channel disk module
(FCDM)
Operations and service
personnel can use the
console best at the middle
U locations.
U20 is recommended.2USystem console
Any available 1U space.
Top of cabinet is
recommended.
1UMaintenance switch
Typical Configuration
Figure 5-1 (page 79) shows the U locations in the 42U modular cabinet of some of the hardware
components that can be installed in the modular cabinet.
78 Hardware Configuration in Modular Cabinets