HP (Hewlett-Packard) 648375-001 Server User Manual


 
Operations 31
CAUTION: For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed.
To install the component:
1. Insert the system air baffle.
2. If removed, install the PCI air baffle (on page 29).
3. For tower models, do the following:
a. Install the access panel (on page 26).
b. Return the server to an upright position.
4. For rack models, do the following:
a. Install the access panel (on page 26).
b. Slide the server back into the rack.
5. Power up the server (on page 22).
6. Do one of the following:
o For tower models, install the bezel ("Install the tower bezel" on page 23).
o For rack models, if removed, install the security bezel ("Security bezel option" on page 47).
Remove the fan cage
To remove the component:
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 22).
o For rack models, if installed, remove the security bezel (on page 24).
2. Power down the server (on page 22).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.