HP (Hewlett-Packard) 648375-001 Server User Manual


 
Hardware options installation 92
11.
Install the PCI air baffle into the server ("Install the PCI air baffle" on page 29).
12. Install the access panel (on page 26).
13. Do one of the following:
o For tower models, return the server to an upright position.
o For rack models, install the server onto the rails.
14. Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
17. Do one of the following:
o For tower models, install the bezel ("Install the rack bezel" on page 25).
o For rack models, if removed, install the security bezel ("Security bezel option" on page 47).
Redundant power supply module
Power redundancy requires the presence of two power supply modules in the system.
CAUTION: All power supplies installed in the server must have the same output power capacity.
Verify that all power supplies have the same part number and label color. The system becomes
unstable and may shut down when it detects mismatched power supplies.
Label color Output
Blue
460 W
Orange
750 W
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.