HP (Hewlett-Packard) HP 9000 V2500 Server User Manual


 
Chapter 2 31
Indicators, switches, and displays
System Displays
Attention light bar
The Attention light bar is located at the top left corner on the front of the
V2500/V2600 server as shown in Figure 17 on page 27. The light bar
displays system status in three ways:
OFF—dc power is turned off. Either the key switch or the side circuit
breaker is in the off position.
ON—Both the side circuit breaker and the keyswitch are in the on
position and no environmental warning, error, or hard error exists.
Flashing—There is an environmental error, warning, or hard error
condition. Also indicates scanning during diagnostic execution.
NOTE The light bar flashing during initial start up does not indicate a fault.
The types of environmental conditions that are monitored include:
ASIC installation error sensing
ASIC configuration or status
48V failure
NOTE 48V failures are cleared only after a power cycle.
Power failure sensing
Fan sensing
Thermal sensing
Types of environmental control functions monitored include:
•Power-on
Voltage margining (SSP interface)
p Multi-node hardware verification
q Multi-node initialization ending synchronization
r Enabling system error hardware.
Message display code Description