HP (Hewlett-Packard) HP-UX 11i v2 Computer Accessories User Manual


 
Configuring gated
Configuring the OSPF Protocol
Chapter 3 69
Default: None (you must specify a value)
Range: Integer between 0 – 255
NOTE The hellointerval value must be the same for all OSPF routers.
routerdeadinterval specifies the time interval (in seconds) for
which the Hello packets are not received from a router before it is
considered down or inactive by its neighbors. This value must be a
multiple of the hellointerval value.
Default: None (you must specify a value)
Range: 0 – 65535
NOTE The routerdeadinterval value must be the same for all OSPF
routers.
You can use the password authkey to validate the protocol packets
received on the router interface. The value can be 1 to 8 decimal
digits separated by periods, a 1-byte to 8-byte hexadecimal string
preceded by 0x, or a string of 1 to 8 characters in double quotes.
Default: None
Range: Up to 8 bytes
NOTE To set an authkey value, you must set the authtype clause to 1 or
simple for the area. See “Authentication” on page 77 for more
information on using OSPF authentication.