HP (Hewlett-Packard) QMS 1660E Printer User Manual


 
The ESP (Emulation Sensing Processor) timeout is the maximum
number of seconds the printer uses to match an emulation before
printing the job in the ESP default emulation (Administration/Emula-
tions/ESP Default Emul menu).
The manual feed timeout is the maximum number of seconds the
printer waits for the next sheet of media to be placed in the manual
feed tray. If the timeout occurs, the manual feed job is canceled. The
multipurpose tray, when accessed by a PostScript emulation operator
as bin 0, is the manual feed tray.
Notes A value of 000 is the same as infinity (no timeout).
When selecting a baud rate of 2400 or below (Administration/
Communications/Serial/Baud Rate menu), increase the
emulation timeout value as follows:
Baud Rate Emulation Timeout (seconds)
2400 10*
1200 20
600 40
300 80
*A baud rate of 2400 works with a 5-second emulation timeout
value, but there is no margin for delays between characters.
Menu Administration/Communications/Timeouts/ESP Timeout
Choices 00000-99999
Default 00003 (3 sec.)
Notes A value of 000 is the same as infinity (no timeout).
Menu Administration/Engine/Man Feed Timeout
Choices 000-300 (0-5 min.)
Default 060 (1 min.)
Notes A value of 000 is the same as infinity (no timeout).