Hitachi 8450H/R Server User Manual


 
Ch 2: Installation and Use of Devices
Hitachi PC VisionBase8450H/R Server 17
9 Close Door Error Blinking The door of the magazine insertion slot of the autoloader is
open. Close the door.
10 Drive comms
Error
Error On Hardware error. Contact the store where you bought the
system equipment or call the maintenance personnel.
11 Eject Fail Error Blinking The eject command terminated abnormally. Use a new
cartridge or attempt a forced ejection.
12 Eject Mag Information This is displayed when the eject button is pressed.
13 Erase Status The drive is erasing data from the tape.
14 Error x Error Blinking The drive has been inoperable. Press the eject button to
remove the cartridge and the magazine. If the error still
recurs, contact the store where you bought the system or
call the maintenance personnel.
15 ForceEject Information ction is in progress.
16 Format Status The SCSI command is being executed to create a tape
with one or two partitions.
The partition size of an existing two-partition tape is being
changed.
17 FRU 1 Dead Error On Hardware error. Contact the store where you bought the
system equipment or call the maintenance personnel.
18 FRU 2 Dead Error On Hardware error. Contact the store where you bought the
system equipment or call the maintenance personnel.
19 FW Check Status The firmware upgrade data is being checked for
compatibility.
20 FW Data Err Error Blinking The firmware upgrade data is incorrect. Use the correct
upgrade data.
21 FW Program Status The drive is being upgraded with new firmware.
22 FW Upgrade Status The firmware upgrade data is being downloaded from tape
or the SCSI bus.
23 FW Read Fail Error Blinking Upgrading of firmware failed because of a read error.
Tryagain. If the error still recurs, contact the store where
you bought the system or call the maintenance personnel.
24 FW Tape Write
Protected
Error Blinking Upgrading of firmware failed because the tape is write-
protected.
25 FW Write Fail Error Blinking Upgrading of firmware failed because of a write error.
Tryagain. If the error still recurs, contact the store where
you bought the system or call the maintenance personnel.
26 Illegal FW Error Blinking Upgrading of firmware failed because the firmware is
incompatible. Use the upgrade data of the correct version.
27 Illegal HW Error Blinking Upgrading of firmware failed because the firmware is
incompatible. Use the upgrade data of the correct version.
28 Insert Mag Status No magazine has been inserted into the autoloader
(Standby).
No. Message Type Operator-
alert lamp
Meaning