Removing the Server Panels and Accessing Its Components
It will be necessary to remove the exterior panels of the unit to access internal components. Be sure to read and
comply with the Safety Guides before proceeding.
Safety Guidelines
Before you remove the top and side covers of the server, observe these guidelines:
1.
Turn off all peripheral devices connected to the server.
2.
Turn off DC power in the server by pressing the push-button on/off power switch on the front panel of the server.
3.
Disconnect AC power to the server by unplugging the alternating current (AC) power cord from each power
supply or wall outlet.
4.
Label and disconnect all peripheral cables attached to the I/O panel on the back of the server.
5.
Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis
ground of the server—any unpainted metal surface—when handling components.
Warnings and Cautions
Only a
qualified service technician
is authorized to remove the server panels and to access any of the components
inside the server.
Tools and Supplies You Need
Phillips (cross-head) screwdriver (#1 bit and #2 bit)
Small flat-bladed screwdriver
Antistatic wrist strap (required)
NOTE:
Bay Extraction tools are provided with the unit, located on the rear of the chassis, and should remain with